        2. Home > Operational Area > TURBINE
          How the titration differential expansion high pressure zero position?

          the titration of high pressure differential expansion zero position and the titration of the turbine axial dispalacement zero position is the same. Steam turbine at full cold condition, the rotor to the generator side of the thrust plate toward the thrust pad face, this time meter reading is zero. Unit during turning in high differential pressure inflation indicator should be some negative (-0.3 ~ 0.4mm).